196 research outputs found

    The "ComPAS Trial" combined treatment model for acute malnutrition: study protocol for the economic evaluation.

    Get PDF
    BACKGROUND: Acute malnutrition is currently divided into severe (SAM) and moderate (MAM) based on level of wasting. SAM and MAM currently have separate treatment protocols and products, managed by separate international agencies. For SAM, the dose of treatment is allocated by the child's weight. A combined and simplified protocol for SAM and MAM, with a standardised dose of ready-to-use therapeutic food (RUTF), is being trialled for non-inferior recovery rates and may be more cost-effective than the current standard protocols for treating SAM and MAM. METHOD: This is the protocol for the economic evaluation of the ComPAS trial, a cluster-randomised controlled, non-inferiority trial that compares a novel combined protocol for treating uncomplicated acute malnutrition compared to the current standard protocol in South Sudan and Kenya. We will calculate the total economic costs of both protocols from a societal perspective, using accounting data, interviews and survey questionnaires. The incremental cost of implementing the combined protocol will be estimated, and all costs and outcomes will be presented as a cost-consequence analysis. Incremental cost-effectiveness ratio will be calculated for primary and secondary outcome, if statistically significant. DISCUSSION: We hypothesise that implementing the combined protocol will be cost-effective due to streamlined logistics at clinic level, reduced length of treatment, especially for MAM, and reduced dosages of RUTF. The findings of this economic evaluation will be important for policymakers, especially given the hypothesised non-inferiority of the main health outcomes. The publication of this protocol aims to improve rigour of conduct and transparency of data collection and analysis. It is also intended to promote inclusion of economic evaluation in other nutrition intervention studies, especially for MAM, and improve comparability with other studies. TRIAL REGISTRATION: ISRCTN 30393230 , date: 16/03/2017

    Cumulative ultraviolet radiation flux in adulthood and risk of incident skin cancers in women

    Get PDF
    Background: Solar ultraviolet (UV) exposure estimated based on residential history has been used as a sun exposure indicator in previous case–control and descriptive studies. However, the associations of cumulative UV exposure based on residential history with different skin cancers, including melanoma, squamous cell carcinoma (SCC), and basal cell carcinoma (BCC), have not been evaluated simultaneously in prospective studies. Methods: We conducted a cohort study among 108 578 women in the Nurses' Health Study (1976–2006) to evaluate the relative risks of skin cancers with cumulative UV flux based on residential history in adulthood. Results: Risk of SCC and BCC was significantly lower for women in lower quintiles vs the highest quintile of cumulative UV flux (both P for trend <0.0001). The association between cumulative UV flux and risk of melanoma did not reach statistical significance. However, risk of melanoma appeared to be lower among women in lower quintiles vs the highest quintile of cumulative UV flux in lag analyses with 2–10 years between exposure and outcome. The multivariable-adjusted hazard ratios per 200 × 10−4 Robertson–Berger units increase in cumulative UV flux were 0.979 (95% confidence interval (CI): 0.933, 1.028) for melanoma, 1.072 (95% CI: 1.041, 1.103) for SCC, and 1.043 (95% CI: 1.034, 1.052) for BCC. Conclusions: Associations with cumulative UV exposure in adulthood among women differed for melanoma, SCC, and BCC, suggesting a potential variable role of UV radiation in adulthood in the carcinogenesis of the three major skin cancers

    Accelerometer and GPS Data to Analyze Built Environments and Physical Activity

    Get PDF
    Purpose: Most built environment studies have quantified characteristics of the areas around participants' homes. However, the environmental exposures for physical activity (PA) are spatially dynamic rather than static. Thus, merged accelerometer and global positioning system (GPS) data were utilized to estimate associations between the built environment and PA among adults. Methods: Participants (N = 142) were recruited on trails in Massachusetts and wore an accelerometer and GPS unit for 1-4 days. Two binary outcomes were created: moderate-to-vigorous PA (MVPA vs. light PA-to-sedentary); and light-to-vigorous PA (LVPA vs. sedentary). Five built environment variables were created within 50-meter buffers around GPS points: population density, street density, land use mix (LUM), greenness, and walkability index. Generalized linear mixed models were fit to examine associations between environmental variables and both outcomes, adjusting for demographic covariates. Results: Overall, in the fully adjusted models, greenness was positively associated with MVPA and LVPA (odds ratios [ORs] = 1.15, 95% confidence interval [CI] = 1.03, 1.30 and 1.25, 95% CI = 1.12, 1.41, respectively). In contrast, street density and LUM were negatively associated with MVPA (ORs = 0.69, 95% CI = 0.67, 0.71 and 0.87, 95% CI = 0.78, 0.97, respectively) and LVPA (ORs = 0.79, 95% CI = 0.77, 0.81 and 0.81, 95% CI = 0.74, 0.90, respectively). Negative associations of population density and walkability with both outcomes reached statistical significance, yet the effect sizes were small. Conclusions: Concurrent monitoring of activity with accelerometers and GPS units allowed us to investigate relationships between objectively measured built environment around GPS points and minute-by-minute PA. Negative relationships between street density and LUM and PA contrast evidence from most built environment studies in adults. However, direct comparisons should be made with caution since most previous studies have focused on spatially fixed buffers around home locations, rather than the precise locations where PA occurs

    Applying synthetic radiography to intraoral tomosynthesis: A step towards achieving 3D imaging in the dental clinic

    Get PDF
    objectives: A practical approach to three-dimensional (3D) intraoral imaging would have many potential applications in clinical dentistry. Stationary intraoral tomosynthesis (sIOT) is an experimental 3D imaging technology that holds promise. The purpose of this study was to explore synthetic radiography as a tool to improve the clinical utility of the images generated by an sIOT scan. Methods: Extracted tooth specimens containing either caries adjacent to restorations (CAR) or vertical root fractures (VRF) were imaged by sIOT and standard dental radiography devices. Qualitative assessments were used to compare the conspicuity of these pathologies in the standard radiographs and in a set of multi-view synthetic radiographs generated from the information collected by sIOT. Results: The sIOT-based synthetic 2D radiographs contained less artefact than the image slices in the reconstructed 3D stack, which is the conventional approach to displaying information from a tomosynthesis scan. As a single sIOT scan can be used to generate synthetic radiographs from multiple viewing angles, the interproximal space was less likely to be obscured in the synthetic images compared to the standard radiograph. Additionally, the multi-view synthetic radiographs can potentially improve the display of CAR and VRFs as compared to a single standard radiograph. conclusions: This preliminary experience combining synthetic radiography and sIOT in extracted tooth models is encouraging and supports the ongoing study of this promising approach to 3D intraoral imaging with many potential applications

    In vitro parameter optimization for spatial control of focused ultrasound ablation when using low boiling point phase-change nanoemulsions

    Get PDF
    Abstract Background Phase-shift nanoemulsions (PSNEs) provide cavitation sites when the perfluorocarbon (PFC) nanodroplets (ND) are vaporized to microbubbles by acoustic energy. Their presence lowers the power required to ablate tissue by high-intensity focused ultrasound (HIFU), potentially making it a safer option for a broader range of treatment sites. However, spatial control over the ablation region can be problematic when cavitation is used to enhance heating. This study explored relationships between vaporization, ablation, and the PSNE concentration in vitro to optimize the acoustic intensity and insonation time required for spatially controlled ablation enhancement using a PSNE that included a volatile PFC component. Methods HIFU (continuous wave at 1 MHz; insonation times of 5, 10, 15, and 20 s; cool-down times of 2, 4, and 6 s; peak negative pressures of 2, 3, and 4 MPa) was applied to albumin-acrylamide gels containing PFC agents (1:1 mix of volatile decafluorobutane and more stable dodecafluoropentane at 105 to 108 PFC ND per milliliter) or agent-free controls. Vaporization fields (microbubble clouds) were imaged by conventional ultrasound, and ablation lesions were measured directly by calipers. Controlled ablation was defined as the production of ‘cigar’-shaped lesions corresponding with the acoustic focal zone. This control was considered to be lost when ablation occurred in prefocal vaporization fields having a predominantly ‘tadpole’ or oblong shape. Results Changes in the vaporization field shape and location occurred on a continuum with increasing PSNE concentration and acoustic intensity. Working with the maximum concentration-intensity combinations resulting in controlled ablation demonstrated a dose-responsive relationship between insonation time and volumes of both the vaporization fields (approximately 20 to 240 mm3) and the ablation lesions (1 to 135 mm3) within them. Conclusions HIFU ablation was enhanced by this PSNE and could be achieved using intensities ≤650 W/cm2. Although the ablation lesions were located within much larger microbubble clouds, optimum insonation times and intensities could be selected to achieve an ablation lesion of desired size and location for a given PSNE concentration. This demonstration of controllable enhancement using a PSNE that contained a volatile PFC component is another step toward developing phase-shift nanotechnology as a potential clinical tool to improve HIFU

    The cost of preventing undernutrition: cost, cost-efficiency and cost-effectiveness of three cash-based interventions on nutrition outcomes in Dadu, Pakistan

    Get PDF
    Cash-based interventions (CBIs) increasingly are being used to deliver humanitarian assistance and there is growing interest in the cost-effectiveness of cash transfers for preventing undernutrition in emergency contexts. The objectives of this study were to assess the costs, cost-efficiency and cost-effectiveness in achieving nutrition outcomes of three CBIs in southern Pakistan: a 'double cash' (DC) transfer, a 'standard cash' (SC) transfer and a 'fresh food voucher' (FFV) transfer. Cash and FFVs were provided to poor households with children aged 6-48 months for 6 months in 2015. The SC and FFV interventions provided 14monthlyandtheDCprovided14 monthly and the DC provided 28 monthly. Cost data were collected via institutional accounting records, interviews, programme observation, document review and household survey. Cost-effectiveness was assessed as cost per case of wasting, stunting and disability-adjusted life year (DALY) averted. Beneficiary costs were higher for the cash groups than the voucher group. Net total cost transfer ratios (TCTRs) were estimated as 1.82 for DC, 2.82 for SC and 2.73 for FFV. Yet, despite the higher operational costs, the FFV TCTR was lower than the SC TCTR when incorporating the participation cost to households, demonstrating the relevance of including beneficiary costs in cost-efficiency estimations. The DC intervention achieved a reduction in wasting, at 4865percaseaverted;neithertheSCnortheFFVinterventionsreducedwasting.Thecostpercaseofstuntingavertedwas4865 per case averted; neither the SC nor the FFV interventions reduced wasting. The cost per case of stunting averted was 1290 for DC, 882forSCand882 for SC and 883 for FFV. The cost per DALY averted was 641forDC,641 for DC, 434 for SC and $563 for FFV without discounting or age weighting. These interventions are highly cost-effective by international thresholds. While it is debatable whether these resource requirements represent a feasible or sustainable investment given low health expenditures in Pakistan, these findings may provide justification for continuing Pakistan's investment in national social safety nets

    Dual-frequency acoustic droplet vaporization detection for medical imaging

    Get PDF
    Liquid-filled perfluorocarbon droplets emit a unique acoustic signature when vaporized into to gas-filled microbubbles using ultrasound. Here, we conducted a pilot study in a tissue-mimicking flow phantom to explore the spatial aspects of droplet vaporization and investigate the effects of applied pressure and droplet concentration on image contrast and axial and lateral resolution. Control microbubble contrast agents were used for comparison. A confocal dual-frequency transducer was used to transmit at 8 MHz and passively receive at 1 MHz. Droplet signals were of significantly higher energy than microbubble signals. This resulted in improved signal separation and high contrast-to-tissue ratios (CTR). Specifically, with a peak negative pressure (PNP) of 450 kPa applied at the focus, the CTR of B-mode images was 18.3 dB for droplets and −0.4 for microbubbles. The lateral resolution was dictated by the size of the droplet activation area, with lower pressures resulting in smaller activation areas and improved lateral resolution (0.67 mm at 450 kPa). The axial resolution in droplet images was dictated by the size of the initial droplet and independent of the properties of the transmit pulse (3.86 mm at 450 kPa). In post-processing, time-domain averaging (TDA) improved droplet and microbubble signal separation at high pressures (640 kPa and 700 kPa). Taken together, these results indicate that it is possible to generate high-sensitivity, high-contrast images of vaporization events. In the future, this has the potential to be applied in combination with droplet-mediated therapy to track treatment outcomes or as a stand-alone diagnostic system to monitor the physical properties of the surrounding environment

    Contrast-Enhanced Ultrasound Imaging and in Vivo Circulatory Kinetics with Low-Boiling-Point Nanoscale Phase-Change Perfluorocarbon Agents

    Get PDF
    Many studies have explored phase-change contrast agents (PCCAs) that can be vaporized by an ultrasonic pulse to form microbubbles for ultrasound imaging and therapy. However, few investigations have been published demonstrating the utility and characteristics of PCCAs as contrast agents in vivo. In this study, we examine the properties of low boiling point nanoscale PCCAs evaluated in vivo, and compare data to conventional microbubbles with respect to contrast generation and circulation properties. In order to do this, we develop a custom pulse sequence to vaporize and image PCCAs using the Verasonics research platform and a clinical array transducer. Results show that droplets can produce similar contrast enhancement to microbubbles (7.29 to 18.24 dB over baseline, depending on formulation), and can be designed to circulate for as much as 3.3 times longer than microbubbles. This study also demonstrates for the first time the ability to capture contrast wash-out kinetics of the target organ as a measure of vascular perfusion

    Phase-shift perfluorocarbon agents enhance high intensity focused ultrasound thermal delivery with reduced near-field heating

    Get PDF
    Ultrasound contrast agents are known to enhance high intensity focused ultrasound (HIFU) ablation, but these perfluorocarbon microbubbles are limited to the vasculature, have a short half-life in vivo, and may result in unintended heating away from the target site. Herein, a nano-sized (100–300 nm), dual perfluorocarbon (decafluorobutane/dodecafluoropentane) droplet that is stable, is sufficiently small to extravasate, and is convertible to micron-sized bubbles upon acoustic activation was investigated. Microbubbles and nanodroplets were incorporated into tissue-mimicking acrylamide-albumin phantoms. Microbubbles or nanodroplets at 0.1 × 106 per cm3 resulted in mean lesion volumes of 80.4 ± 33.1 mm3 and 52.8 ± 14.2 mm3 (mean ± s.e.), respectively, after 20 s of continuous 1 MHz HIFU at a peak negative pressure of 4 MPa, compared to a lesion volume of 1.0 ± 0.8 mm3 in agent-free control phantoms. Magnetic resonance thermometry mapping during HIFU confirmed undesired surface heating in phantoms containing microbubbles, whereas heating occurred at the acoustic focus of phantoms containing the nanodroplets. Maximal change in temperature at the target site was enhanced by 16.9% and 37.0% by microbubbles and nanodroplets, respectively. This perfluorocarbon nanodroplet has the potential to reduce the time to ablate tumors by one-third during focused ultrasound surgery while also safely enhancing thermal deposition at the target site
    • …
    corecore